US model comparison
EcoFlow DELTA 3 Plus vs Anker SOLIX C1000
The original C1000 stores 32 Wh more. Both supply 1,800 W continuously. The DELTA accepts up to 1,000 W of solar across two ports, while the C1000 accepts up to 600 W through one.
Runtime estimate
How long at your load?
Full battery · 80% usable through AC
Choose by the panels you can deploy
At 90 W the original C1000’s extra 32 Wh of nominal capacity buys roughly 17 minutes under the 80% assumption. Both models have the continuous output for a 1,200 W hot plate, subject to individual outlet limits. Their storage and sustained output are close enough that an existing solar setup can decide the purchase.
The C1000 accepts up to 600 W through one input. The DELTA 3 Plus accepts up to 500 W on either input or 1,000 W across both. For one panel, check its voltage and current against the single port. A second 400 W Lightweight panel gives the DELTA an explicitly documented way to use its second input. EcoFlow DELTA 3 Plus lists a switchover time of 10 ms (UPS). Anker SOLIX C1000 lists 20 ms (UPS).
Would either station cover your session?
The two stations give different results on 2 of the 28 example schedules. The examples below are sized for the smaller station.
| Editable session | Energy / running load | EcoFlow DELTA 3 Plus | Anker SOLIX C1000 |
|---|---|---|---|
| Portable power stations for camping | 205 Wh / 97 W | 614.2 Wh left | 639.8 Wh left |
| Portable power stations for home backup | 914 Wh / 180 W | 94.8 Wh short | 69.2 Wh short |
| Portable power for a CPAP machine overnight | 176 Wh / 22 W | 643.2 Wh left | 668.8 Wh left |
Full base battery, 80% usable energy, no recharge. Each result checks total energy and simultaneous running watts. Verify individual outlets and startup loads separately.
Compare specifications
| Specification | EcoFlow DELTA 3 Plus | Anker SOLIX C1000 |
|---|---|---|
| Battery capacity | 1,024 Wh | 1,056 Wh |
| Continuous AC | 1,800 W | 1,800 W |
| AC surge | 3,600 W | |
| Total solar input | 1,000 W | 600 W |
| AC charging time | 56 min to 100% | 58 min to 100% |
| Maximum AC input | 1,500 W | 1,300 W |
| Weight | 27.6 lb | 28.44 lb |
| AC outlets | — | 6 |
| USB-C ports | — | 2, up to 100 W |
| USB-A ports | — | 2 |
| Car outlet | Yes | Yes |
| Expandable | Yes with DELTA 3 Smart Extra Battery (EF-DL-E10-4), DELTA Pro 3 Smart Extra Battery (EFD521-EB), DELTA 2 Smart Extra Battery (EFD330-EB), DELTA 2 Max Smart Extra Battery (EFD350-EB), DELTA Max Smart Extra Battery (EFD310-EB) | Yes, to 2,112 Wh with Anker SOLIX BP1000 |
| Switchover time | UPS, 10 ms | UPS, 20 ms |
| Battery chemistry and cycle life | LFP, 4,000 cycles to 80% | LFP, 3,000 cycles to 80% |
| Warranty | 5 years | 5 years |
| Solar inputs | 2 | 1 |
| Estimated time at 100 W | 8.2 h | 8.4 h |
| Estimated time at 500 W | 1.6 h | 1.7 h |
| Estimated time at 1500 W | 33 min | 34 min |
Estimates assume a steady load and 80% usable energy. Adjust the assumptions.
Panel choices
EcoFlow DELTA 3 Plus
EcoFlow’s 400 W Lightweight panel manual lists two panels for the DELTA 3 Plus, one on each solar input. That pair provides 800 W of panel nameplate capacity, within the combined 1,000 W station rating. Each individual port accepts up to 500 W. The extra input is useful when you have space to deploy both panels and enough sunlight to use them.
EcoFlow 400 W Lightweight panel manual (PDF), model compatibility tableAnker SOLIX C1000
One Anker PS200 (200 W) or one PS400 (400 W) is a documented match for the original C1000. Its single XT60 input accepts up to 600 W. The manual lists different current limits across that voltage range, with 10 A for 11–32 V and 12.5 A for 32–60 V. At an operating voltage of 20 V, the 10 A input limit caps charging at about 200 W even in strong sun.
Anker’s C1000 panel compatibility listModel-specific limits
EcoFlow DELTA 3 Plus
The Plus has two 500 W solar inputs. A panel array connected to a single port can deliver up to 500 W.
Anker SOLIX C1000
The original C1000 is model A1761. Its US guide rates the inverter at 1,800 W. Anker’s 2,400 W SurgePad mode is intended for certain loads, such as heating elements. Sizing a motor requires a separate startup rating.