All models / EcoFlow

US model guide

EcoFlow DELTA 2

The DELTA 2 suits a desk or campsite with modest overnight demand and occasional short cooking loads. Its six AC outlets share enough output for a 1,500 W appliance.

Battery capacity
1,024 Wh
Continuous AC
1,800 W
Surge AC
2,700 W
Total solar input
500 W

Charging, weight and outlets

SpecificationValue
AC charging time1 h 12 min to 100%
Maximum AC input1,200 W
Weight27 lb
AC outlets6
USB-C ports2, up to 100 W
USB-A ports4
Car outletYes
ExpandableYes with DELTA 2 Smart Extra Battery (EFD330-EB)
Switchover timeEPS, 30 ms
Battery chemistry and cycle lifeLFP, 3,000 cycles to 80%
Warranty5 years

Runtime estimate

How long at your load?

Full battery · 80% usable through AC

EcoFlow DELTA 28.2 h

Which sessions fit this battery?

These are common sessions for a battery of this size. Open a schedule to change the appliances or hours and see whether your own setup fits.

Editable sessionEnergy / running loadEstimated outcome
Portable power stations for camping205 Wh / 97 W614.2 Wh left
Portable power stations for home backup914 Wh / 180 W94.8 Wh short
Portable power for a CPAP machine overnight176 Wh / 22 W643.2 Wh left

Full base battery, 80% usable energy, no recharge. Each result checks total energy and simultaneous running watts. Verify individual outlets and startup loads separately.

What it can run

Consider a 90 W laptop-and-monitor setup for six hours and a 1,500 W kettle for six minutes. The desk uses 540 Wh and the kettle uses another 150 Wh. That leaves about 129 Wh of the estimated 819 Wh AC budget, even though the kettle briefly draws far more power than the desk. Running both together would draw 1,590 W, below the 1,800 W combined AC rating. Substitute measured input power and time for your own appliances.

Example AC loadAssumed drawEstimated running time
LED task lamp15 W54.6 h
Laptop and monitor90 W9.1 h
Desktop workstation250 W3.3 h
Small slow cooker on high200 W4.1 h
Electric hot plate on high1,200 W41 min

The examples assume the listed wall draw holds steady and 80% of a full battery reaches the load. The lamp estimate is especially sensitive to inverter idle draw. Thermostats, motor startup and power-saving modes change the result. For a cycling device, use measured average watts for energy and check peak starting demand separately.

Calculate with your own appliance wattage

Which solar panels fit?

The EcoFlow 400 W Lightweight panel manual lists one panel on the DELTA 2’s single solar input. Its 400 W nameplate leaves 100 W of headroom under the station’s 500 W ceiling. If the panel actually supplies 200 W for three hours, 600 Wh reaches the input before charging losses. This is a useful scale for planning the next evening’s loads.

EcoFlow 400 W Lightweight panel manual (PDF), model compatibility table

InputPortsVoltage rangeCurrent limitPower per port
Solar input1
11–60 V
15 A
500 W

The six AC outlets share a 1,800 W inverter. The US manual separately lists a 2,700 W surge rating for short peaks.

Compare solar inputs across models

Closest alternatives

  • EcoFlow DELTA 3 — The DELTA 3 matches the DELTA 2’s capacity, continuous AC output and solar ceiling. Its 3,600 W published surge exceeds the DELTA 2’s 2,700 W, a reason to check the newer unit if measured startup demand is your constraint.
  • EcoFlow DELTA 2 Max — The Max doubles capacity to 2,048 Wh, so the same desk-and-kettle day uses about 42% of its estimated usable energy. The smaller DELTA 2 weighs about 27 lb versus about 50 lb for the Max.

Side by side

Manufacturer sources

Checked November 23, 2026.