Plug-in solar / Maine

Plug-in solar law

Maine plug-in solar law

Maine plug-in solar law: enacted. The limit is 1,200 W.

Law status checked November 23, 2026. This is general information, not legal advice. Confirm with your utility before you connect a device.

The chaptered text we read gives no effective date.

Bill
L.D. 1730 (S.P. 676), Public Law 2026 c. 644, 35-A MRSA 3475
Status
Enacted
Signed
April 6, 2026
Effective
Not confirmed
Maximum output
1,200 W

Maximum output

Bill text:

"Eligible system" means a plug-in photovoltaic system or plug-in battery system with an export capacity of 1,200 watts or less ... "A retail electricity customer may install and operate one or more eligible systems with a combined inverter output of up to 420 watts, measured in alternating current, per service address. ... [Systems] exceeding 420 watts, but no more than 1,200 watts, per service address, [are allowed] as long as each system is installed by an electrician licensed in the State and uses a dedicated circuit with a single outlet and the customer complies with the notification requirement"

Certification and safety

"(1) Listed or certified in accordance with UL 3700, the Outline of Investigation for Interactive Plug-in Photovoltaic Equipment and Systems, and any other applicable standards developed by UL LLC ... or the National Electrical Code specific to plug-in photovoltaic systems and plug-in battery systems; (2) Listed or certified in accordance with a standard comparable to UL 3700 from a nationally recognized testing laboratory; or (3) Configured in accordance with the National Electrical Code that is adopted by rule by the Electricians' Examining Board." PV systems must use "inverters that are configured to shut off after 0.2 seconds if power is disrupted."

Utility notice and approval

Customer notice required only above 420 W: "within 30 days of installation" in a form prescribed by the commission. Utility may not require approval, an interconnection application/agreement/study, any fee, or additional controls; "may not deny the installation of an eligible system that complies." Not eligible for net energy billing. Utility not liable.

Landlord and HOA rules

Subsection 8: a customer installing on a structure the customer does not own must ensure it does not "compromise the integrity of the structure or violate any state or local building, fire or zoning codes" and restore the structure on removal. Covers plug-in battery systems as well as PV. The chaptered text has no express landlord-permission or HOA clause.

Other conditions

Covers plug-in battery systems (AC-coupled, standard outlet). Two tiers: 420 W without electrician, up to 1,200 W with licensed electrician, dedicated single-outlet circuit and utility notification.

Sources

Related

Plug-in solar overview, is plug-in solar legal and plug-in solar kits.