All models / EcoFlow

US model guide

EcoFlow DELTA (1,260 Wh)

An owner guide for the original high-capacity DELTA. The listed ratings fit occasional high-power appliances and a longer session of electronics.

Battery capacity
1,260 Wh
Continuous AC
1,800 W
Surge AC
3,300 W
Total solar input
400 W

Charging, weight and outlets

SpecificationValue
Maximum AC input1,200 W
Weight30.9 lb
AC outlets6
USB-C ports2, up to 60 W
USB-A ports4
Car outletYes
Switchover timeEPS, 30 ms
Battery chemistry and cycle lifeNMC, 800 cycles to 80%
Warranty2 years

Runtime estimate

How long at your load?

Full battery · 80% usable through AC

EcoFlow DELTA (1,260 Wh)10.1 h

Which sessions fit this battery?

These are common sessions for a battery of this size. Open a schedule to change the appliances or hours and see whether your own setup fits.

Editable sessionEnergy / running loadEstimated outcome
Portable power stations for camping205 Wh / 97 W803 Wh left
Portable power stations for home backup914 Wh / 180 W94 Wh left
Portable power for a CPAP machine overnight176 Wh / 22 W832 Wh left

Full base battery, 80% usable energy, no recharge. Each result checks total energy and simultaneous running watts. Verify individual outlets and startup loads separately.

What it can run

At 80% usable capacity the base battery supplies about 1,008 Wh through AC. A 1,400 W oven drawing full power for 20 minutes uses roughly 467 Wh, leaving about 541 Wh to run a 90 W desk for six hours. On an older unit, a measured capacity check is especially useful before relying on that margin.

Example AC loadAssumed drawEstimated running time
LED task lamp15 W67.2 h
Laptop and monitor90 W11.2 h
Desktop workstation250 W4 h
Small slow cooker on high200 W5 h
Electric hot plate on high1,200 W50 min

The examples assume the listed wall draw holds steady and 80% of a full battery reaches the load. The lamp estimate is especially sensitive to inverter idle draw. Thermostats, motor startup and power-saving modes change the result. For a cycling device, use measured average watts for energy and check peak starting demand separately.

Calculate with your own appliance wattage

Which solar panels fit?

The manual requires panel output voltage within 65 V and allows up to two sets of panels in parallel with an optional parallel cable. The station’s solar limit is 400 W. Over three hours at a measured 100 W, about 300 Wh arrives at the input before conversion losses.

EcoFlow DELTA (1,260 Wh) user manual, US specifications (PDF)

InputPortsVoltage rangeCurrent limitPower per port
Solar input1
10–65 V
10 A
400 W

The original DELTA manual also covers a 1,008 Wh version with a lower output rating. Match the 1,260 Wh label before using these estimates.

Compare solar inputs across models

Closest alternatives

  • EcoFlow DELTA 2 — DELTA 2 also supplies 1,800 W and stores 236 Wh less, while accepting up to 500 W solar compared with 400 W here.
  • EcoFlow DELTA 2 Max — The Max adds 788 Wh and lifts continuous output to 2,400 W for longer or heavier sessions.

Side by side

Manufacturer sources

Checked November 23, 2026.