US model guide
EcoFlow DELTA (1,260 Wh)
An owner guide for the original high-capacity DELTA. The listed ratings fit occasional high-power appliances and a longer session of electronics.
- Battery capacity
- 1,260 Wh
- Continuous AC
- 1,800 W
- Surge AC
- 3,300 W
- Total solar input
- 400 W
Charging, weight and outlets
| Specification | Value |
|---|---|
| Maximum AC input | 1,200 W |
| Weight | 30.9 lb |
| AC outlets | 6 |
| USB-C ports | 2, up to 60 W |
| USB-A ports | 4 |
| Car outlet | Yes |
| Switchover time | EPS, 30 ms |
| Battery chemistry and cycle life | NMC, 800 cycles to 80% |
| Warranty | 2 years |
Runtime estimate
How long at your load?
Full battery · 80% usable through AC
Which sessions fit this battery?
These are common sessions for a battery of this size. Open a schedule to change the appliances or hours and see whether your own setup fits.
| Editable session | Energy / running load | Estimated outcome |
|---|---|---|
| Portable power stations for camping | 205 Wh / 97 W | 803 Wh left |
| Portable power stations for home backup | 914 Wh / 180 W | 94 Wh left |
| Portable power for a CPAP machine overnight | 176 Wh / 22 W | 832 Wh left |
Full base battery, 80% usable energy, no recharge. Each result checks total energy and simultaneous running watts. Verify individual outlets and startup loads separately.
What it can run
At 80% usable capacity the base battery supplies about 1,008 Wh through AC. A 1,400 W oven drawing full power for 20 minutes uses roughly 467 Wh, leaving about 541 Wh to run a 90 W desk for six hours. On an older unit, a measured capacity check is especially useful before relying on that margin.
| Example AC load | Assumed draw | Estimated running time |
|---|---|---|
| LED task lamp | 15 W | 67.2 h |
| Laptop and monitor | 90 W | 11.2 h |
| Desktop workstation | 250 W | 4 h |
| Small slow cooker on high | 200 W | 5 h |
| Electric hot plate on high | 1,200 W | 50 min |
The examples assume the listed wall draw holds steady and 80% of a full battery reaches the load. The lamp estimate is especially sensitive to inverter idle draw. Thermostats, motor startup and power-saving modes change the result. For a cycling device, use measured average watts for energy and check peak starting demand separately.
Which solar panels fit?
The manual requires panel output voltage within 65 V and allows up to two sets of panels in parallel with an optional parallel cable. The station’s solar limit is 400 W. Over three hours at a measured 100 W, about 300 Wh arrives at the input before conversion losses.
EcoFlow DELTA (1,260 Wh) user manual, US specifications (PDF)
| Input | Ports | Voltage range | Current limit | Power per port |
|---|---|---|---|---|
| Solar input | 1 | 10–65 V | 10 A | 400 W |
The original DELTA manual also covers a 1,008 Wh version with a lower output rating. Match the 1,260 Wh label before using these estimates.
Closest alternatives
- EcoFlow DELTA 2 — DELTA 2 also supplies 1,800 W and stores 236 Wh less, while accepting up to 500 W solar compared with 400 W here.
- EcoFlow DELTA 2 Max — The Max adds 788 Wh and lifts continuous output to 2,400 W for longer or heavier sessions.
Side by side
Manufacturer sources
Checked November 23, 2026.