Power station sizing for a 3D print

A heated bed can draw much more during warmup than during the print. Measure both phases and budget the entire job.

How the schedule changes the buying decision

Keep one preheat and run the printer for twelve hours at the measured 115 W printing average.

Example scheduleOne six-hour printTwelve-hour print
Printer preheat0.2 h × 320 W0.2 h × 320 W
Printing at measured average6 h × 115 W12 h × 115 W
Energy used754 Wh1,444 Wh
Battery needed at 80%942.5 Wh1,805 Wh
Simultaneous running load320 W320 W
Models meeting both figures4625
Smallest qualifying battery in the catalogGoal Zero Yeti 1000X
997 Wh battery · 1,500 W AC
EcoFlow DELTA Max 2000
2,016 Wh battery · 2,400 W AC

Doubling printing time adds 690 Wh. The warmup energy stays at 64 Wh because the bed only preheats once. If you split the work into two jobs that both start cold, add the second warmup as well. Budget a reserve to let the final layers and cooldown complete.

Bed temperature, enclosure and material can change the average. A short test print may spend a disproportionate share of its time heating. Measure a representative run at the intended settings.

Size your own setup

Edit the illustrative watts and hours using your readings. Include overlapping loads in the simultaneous watts field. The estimate assumes a full base battery and no recharge. Confirm individual outlets, momentary startup demand and waveform with the manufacturer.

Session assumptions
AC applianceWatts while activeActive hoursEnergy (Wh)
Printer preheat64
Printing at measured average690

Session energy: 754 Wh. Minimum rated capacity: 942.5 Wh at 80% usable. Running output: 320 W.

See matching stations 46 matching models, ordered by nominal capacity.
US modelBatteryContinuous ACEstimated energy left
Goal Zero Yeti 1000X997 Wh1,500 W43.6 Wh
Jackery Explorer 10001,002 Wh1,000 W47.6 Wh
EcoFlow DELTA 3 Plus1,024 Wh1,800 W65.2 Wh
EcoFlow DELTA 21,024 Wh1,800 W65.2 Wh
EcoFlow DELTA 31,024 Wh1,800 W65.2 Wh
DJI Power 10001,024 Wh1,800 W65.2 Wh
BLUETTI Elite 100 V21,024 Wh1,800 W65.2 Wh
EcoFlow DELTA 3 Classic1,024 Wh1,800 W65.2 Wh
Anker SOLIX C1000 Gen 21,024 Wh2,000 W65.2 Wh
Anker SOLIX C10001,056 Wh1,800 W90.8 Wh
Jackery Explorer 1000 v21,070 Wh1,500 W102 Wh
BLUETTI AC1801,152 Wh1,800 W167.6 Wh
EcoFlow DELTA (1,260 Wh)1,260 Wh1,800 W254 Wh
Jackery Explorer 1000 Plus1,264 Wh2,000 W257.2 Wh
BLUETTI AC180P1,440 Wh1,800 W398 Wh
Goal Zero Yeti 1500X1,516 Wh2,000 W458.8 Wh
Jackery Explorer 15001,534.68 Wh1,800 W473.7 Wh
Jackery Explorer 1500 v21,536 Wh2,000 W474.8 Wh
BLUETTI AC2401,536 Wh2,400 W474.8 Wh
EcoFlow DELTA 3 15001,536 Wh1,800 W474.8 Wh
VTOMAN FlashSpeed 15001,548 Wh1,500 W484.4 Wh
EcoFlow DELTA Max 20002,016 Wh2,400 W858.8 Wh
Jackery Explorer 2000 v22,042 Wh2,200 W879.6 Wh
Jackery Explorer 2000 Plus2,042.8 Wh3,000 W880.2 Wh
EcoFlow DELTA 2 Max2,048 Wh2,400 W884.4 Wh
EcoFlow DELTA 3 Max2,048 Wh2,400 W884.4 Wh
BLUETTI AC200L2,048 Wh2,400 W884.4 Wh
Anker SOLIX F20002,048 Wh2,400 W884.4 Wh
BLUETTI AC200MAX2,048 Wh2,200 W884.4 Wh
Anker SOLIX C2000 Gen 22,048 Wh2,400 W884.4 Wh
DJI Power 20002,048 Wh3,000 W884.4 Wh
BLUETTI Elite 200 V22,073.6 Wh2,600 W904.9 Wh
Anker SOLIX F26002,560 Wh2,400 W1,294 Wh
BLUETTI Apex 3002,764.8 Wh3,840 W1,457.8 Wh
Jackery Explorer 3000 Pro3,024 Wh3,000 W1,665.2 Wh
EcoFlow DELTA 3 Ultra Plus3,072 Wh3,600 W1,703.6 Wh
Anker SOLIX F30003,072 Wh3,600 W1,703.6 Wh
Pecron F3000LFP3,072 Wh3,600 W1,703.6 Wh
Jackery HomePower 30003,072 Wh3,600 W1,703.6 Wh
EcoFlow DELTA Pro3,600 Wh3,600 W2,126 Wh
Anker SOLIX F3800 Plus3,840 Wh6,000 W2,318 Wh
Anker SOLIX F38003,840 Wh6,000 W2,318 Wh
EcoFlow DELTA Pro 34,096 Wh4,000 W2,522.8 Wh
Jackery Explorer 5000 Plus5,040 Wh7,200 W3,278 Wh
EcoFlow DELTA Pro Ultra6,144 Wh7,200 W4,161.2 Wh
Anker SOLIX E106,144 Wh7,680 W4,161.2 Wh

Before choosing

Check how the printer handles a power interruption before relying on transfer or auto-resume features. Keep capacity for cooldown and the final portion of a long print.

Virginia Tech appliance energy calculation guide

Compare runtime at one continuous load