Home & outages
Portable power for a sump pump
A sump pump runs only when water rises, but it must run when the grid is down. Size the battery from how many minutes per hour it actually runs.
How the schedule changes the buying decision
Heavy rain doubles the time the pump runs, from ten minutes an hour to twenty, over the same 24 hours.
| Example schedule | Ten minutes of every hour | Twenty minutes of every hour |
|---|---|---|
| 1/3 hp sump pump while running | 4 h × 598 W | 8 h × 598 W |
| Energy used | 2,392 Wh | 4,784 Wh |
| Battery needed at 80% | 2,990 Wh | 5,980 Wh |
| Simultaneous running load | 598 W | 598 W |
| Models meeting both figures | 12 | 2 |
| Smallest qualifying battery in the catalog | Jackery Explorer 3000 Pro 3,024 Wh battery · 3,000 W AC | EcoFlow DELTA Pro Ultra 6,144 Wh battery · 7,200 W AC |
Doubling the run time adds 2,392 Wh. The running watts stay at 598 W. The pump’s startup surge is a separate check and is higher than this. Time how long your pump runs in a storm and enter that number in the worksheet.
The 598 W figure is 115 V times the 5.2 A full-load current printed in Liberty Pumps’ 250-Series sheet for the 1/3 hp model 257. That is apparent power, so measured watts may be lower. The example assumes the pump runs ten minutes of every hour for 24 hours, which is 4 hours of running. That duty cycle is an assumption, because makers do not publish run time. Zoeller lists 4.8 to 9.7 A for its 3/10 hp M53 series, so check the nameplate on your own pump.
Size your own setup
Edit the illustrative watts and hours using your readings. Include overlapping loads in the simultaneous watts field. The estimate assumes a full base battery and no recharge. Confirm individual outlets, momentary startup demand and waveform with the manufacturer.
Session energy: 2,392 Wh. Minimum rated capacity: 2,990 Wh at 80% usable. Running output: 598 W.
See matching stations 12 matching models, ordered by nominal capacity.
| US model | Battery | Continuous AC | Estimated energy left |
|---|---|---|---|
| Westinghouse iGen160s | 155 Wh | 100 W | -2,268 Wh |
| BLUETTI AC2A | 204.8 Wh | 300 W | -2,228.2 Wh |
| Jackery Explorer 240 | 241 Wh | 200 W | -2,199.2 Wh |
| EcoFlow RIVER 3 | 245 Wh | 300 W | -2,196 Wh |
| EcoFlow RIVER 2 | 256 Wh | 300 W | -2,187.2 Wh |
| Jackery Explorer 240 v2 | 256 Wh | 300 W | -2,187.2 Wh |
| Anker 521 PowerHouse 256Wh | 256 Wh | 200 W | -2,187.2 Wh |
| BLUETTI EB3A | 268.8 Wh | 600 W | -2,177 Wh |
| EcoFlow RIVER 3 Plus | 286 Wh | 600 W | -2,163.2 Wh |
| EcoFlow RIVER (288 Wh) | 288 Wh | 600 W | -2,161.6 Wh |
| Jackery Explorer 300 Plus | 288 Wh | 300 W | -2,161.6 Wh |
| Anker SOLIX C300 | 288 Wh | 300 W | -2,161.6 Wh |
| Jackery Explorer 300 | 293.8 Wh | 300 W | -2,157 Wh |
| Goal Zero Yeti 500X | 505 Wh | 300 W | -1,988 Wh |
| EcoFlow RIVER 2 Max | 512 Wh | 500 W | -1,982.4 Wh |
| DJI Power 500 | 512 Wh | 800 W | -1,982.4 Wh |
| Jackery Explorer 500 | 518.4 Wh | 500 W | -1,977.3 Wh |
| EcoFlow RIVER Max | 576 Wh | 600 W | -1,931.2 Wh |
| Jackery Explorer 600 Plus | 632.3 Wh | 800 W | -1,886.2 Wh |
| EcoFlow RIVER Pro | 720 Wh | 600 W | -1,816 Wh |
| EcoFlow RIVER 2 Pro | 768 Wh | 800 W | -1,777.6 Wh |
| BLUETTI AC70 | 768 Wh | 1,000 W | -1,777.6 Wh |
| Anker SOLIX C800 | 768 Wh | 1,200 W | -1,777.6 Wh |
| EcoFlow DELTA mini | 882 Wh | 1,400 W | -1,686.4 Wh |
| Goal Zero Yeti 1000X | 997 Wh | 1,500 W | -1,594.4 Wh |
| Jackery Explorer 1000 | 1,002 Wh | 1,000 W | -1,590.4 Wh |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 1,800 W | -1,572.8 Wh |
| EcoFlow DELTA 2 | 1,024 Wh | 1,800 W | -1,572.8 Wh |
| EcoFlow DELTA 3 | 1,024 Wh | 1,800 W | -1,572.8 Wh |
| DJI Power 1000 | 1,024 Wh | 1,800 W | -1,572.8 Wh |
| BLUETTI Elite 100 V2 | 1,024 Wh | 1,800 W | -1,572.8 Wh |
| EcoFlow DELTA 3 Classic | 1,024 Wh | 1,800 W | -1,572.8 Wh |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 2,000 W | -1,572.8 Wh |
| Anker SOLIX C1000 | 1,056 Wh | 1,800 W | -1,547.2 Wh |
| Jackery Explorer 1000 v2 | 1,070 Wh | 1,500 W | -1,536 Wh |
| BLUETTI AC180 | 1,152 Wh | 1,800 W | -1,470.4 Wh |
| EcoFlow DELTA (1,260 Wh) | 1,260 Wh | 1,800 W | -1,384 Wh |
| Jackery Explorer 1000 Plus | 1,264 Wh | 2,000 W | -1,380.8 Wh |
| BLUETTI AC180P | 1,440 Wh | 1,800 W | -1,240 Wh |
| Goal Zero Yeti 1500X | 1,516 Wh | 2,000 W | -1,179.2 Wh |
| Jackery Explorer 1500 | 1,534.68 Wh | 1,800 W | -1,164.3 Wh |
| Jackery Explorer 1500 v2 | 1,536 Wh | 2,000 W | -1,163.2 Wh |
| BLUETTI AC240 | 1,536 Wh | 2,400 W | -1,163.2 Wh |
| EcoFlow DELTA 3 1500 | 1,536 Wh | 1,800 W | -1,163.2 Wh |
| VTOMAN FlashSpeed 1500 | 1,548 Wh | 1,500 W | -1,153.6 Wh |
| EcoFlow DELTA Max 2000 | 2,016 Wh | 2,400 W | -779.2 Wh |
| Jackery Explorer 2000 v2 | 2,042 Wh | 2,200 W | -758.4 Wh |
| Jackery Explorer 2000 Plus | 2,042.8 Wh | 3,000 W | -757.8 Wh |
| EcoFlow DELTA 2 Max | 2,048 Wh | 2,400 W | -753.6 Wh |
| EcoFlow DELTA 3 Max | 2,048 Wh | 2,400 W | -753.6 Wh |
| BLUETTI AC200L | 2,048 Wh | 2,400 W | -753.6 Wh |
| Anker SOLIX F2000 | 2,048 Wh | 2,400 W | -753.6 Wh |
| BLUETTI AC200MAX | 2,048 Wh | 2,200 W | -753.6 Wh |
| Anker SOLIX C2000 Gen 2 | 2,048 Wh | 2,400 W | -753.6 Wh |
| DJI Power 2000 | 2,048 Wh | 3,000 W | -753.6 Wh |
| BLUETTI Elite 200 V2 | 2,073.6 Wh | 2,600 W | -733.1 Wh |
| Anker SOLIX F2600 | 2,560 Wh | 2,400 W | -344 Wh |
| BLUETTI Apex 300 | 2,764.8 Wh | 3,840 W | -180.2 Wh |
| Jackery Explorer 3000 Pro | 3,024 Wh | 3,000 W | 27.2 Wh |
| EcoFlow DELTA 3 Ultra Plus | 3,072 Wh | 3,600 W | 65.6 Wh |
| Anker SOLIX F3000 | 3,072 Wh | 3,600 W | 65.6 Wh |
| Pecron F3000LFP | 3,072 Wh | 3,600 W | 65.6 Wh |
| Jackery HomePower 3000 | 3,072 Wh | 3,600 W | 65.6 Wh |
| EcoFlow DELTA Pro | 3,600 Wh | 3,600 W | 488 Wh |
| Anker SOLIX F3800 Plus | 3,840 Wh | 6,000 W | 680 Wh |
| Anker SOLIX F3800 | 3,840 Wh | 6,000 W | 680 Wh |
| EcoFlow DELTA Pro 3 | 4,096 Wh | 4,000 W | 884.8 Wh |
| Jackery Explorer 5000 Plus | 5,040 Wh | 7,200 W | 1,640 Wh |
| EcoFlow DELTA Pro Ultra | 6,144 Wh | 7,200 W | 2,523.2 Wh |
| Anker SOLIX E10 | 6,144 Wh | 7,680 W | 2,523.2 Wh |
Before choosing
A motor draws several times its running current for a moment at startup. Neither maker’s sheet we opened gives a startup or locked-rotor figure for these pumps, so measure it with a clamp meter or ask the maker. The station’s surge rating must cover it, not just the running watts. Confirm the pump will restart after the station’s low-voltage cutoff and test the float switch on battery before a storm.
Virginia Tech appliance energy calculation guideManufacturer sources: Liberty Pumps: 250-Series sump pump sheet (model 257, 1/3 hp 115 V 5.2 A) · Zoeller: Mighty-Mate M53 catalog sheet